Plunger check valves

  • Replaceable Kel-F seat discs
  • Cleaned for Oxygen use per CGA G-4.1
  • Can be installed horizontally or vertically
  • Low flow rate

Self-actuated valves like lift check valves use gravity and the pressure of the product to operate. This feature ensures the valve closing off when undesired back-flow occurs.

Body:
Bronze
Cap:
Brass
Plunger:
Brass
Seat:
PCTFE
Gas types:
Argon, CO2, Hydrogen, NG (Natural Gas), Nitrogen, Oxygen
Connections:
Braze, Thread
Types:
NPT
Pressure range:
41 bar (600 psi)
Opening pressure:
140 mbar (2 psi)
Temperature range:
-196˚C to +74˚C (-320˚F to +165˚F)
Sizes and range:
1" to 1½"
Series available:
0541, 05413, 8500
Standards:
EN1626, TPED

*Materials and specifications are subject to generalisation. Our experienced people are ready to help you find the correct fit for your application.

Body:
Bronze
Cap:
Brass
Plunger:
Brass
Seat:
PCTFE
Gas types:
Argon, CO2, Hydrogen, NG (Natural Gas), Nitrogen, Oxygen
Connections:
Braze, Thread
Types:
NPT
Pressure range:
41 bar (600 psi)
Opening pressure:
140 mbar (2 psi)
Temperature range:
-196˚C to +74˚C (-320˚F to +165˚F)
Sizes and range:
1" to 1½"
Series available:
0541, 05413, 8500
Standards:
EN1626, TPED

*Materials and specifications are subject to generalisation. Our experienced people are ready to help you find the correct fit for your application.

Alternative products

No related products were found.

Did you know?

Self-centering cap keeps plunger in position.

Installed vertically, make sure that the flow runs from bottom to top.